H3R Performance MX250C MaxOut Dry Chemical Chrome Fire Extinguisher 2.5 lb. We are proud to offer high quality USA-made, UL listed HalguardT chrome fire extinguishers from H3R Performance. HalGuardT is a premium "clean agent" fire extinguisher that does not leave a messy residue making it the perfect product for protecting classic collector, high performance, tuner and race cars. These chrome fire extinguishers are available in a 2.5 pound size size (extinguishing agent) and the gross weight of the unit is 5.0 pounds; which is ideal for street rods, race cars, trucks or SUVs. These chrome fire extinguishers have a 9-foot to 15-foot discharge range and are fully rechargeable.

H3R Model MX250C - Chrome Dry Chemical Fire Extinguisher. Extinguishing Agent: Mono ammonium phosphate.

Agent Pound: 2.5 pounds. Gross Weight: 5.0 pounds. Gleaming chrome finish adds an extra touch of class to any vehicle. These proven ABC fire extinguishers utilize a specially fluidized and siliconized mono ammonium phosphate dry chemical. It chemically insulates Class A fires by melting at approximately 350°F and coats surface to which it is applied. It smothers and breaks the chain reaction of Class B fires and will not conduct electricity back to the operator. Listed and rated by 1A:10B:C by Underwriters Laboratories. US Coast Guard approved with standard bracket (listed on UL label). 2 strap steel mounting bracket. 9' - 15' discharge range.

Compact, lightweight, easy to use. How can I get my extinguisher recharged?

In addition to undergoing a 6-year maintenance and a 12-year hydrostatic test conducted by a licensed fire service company, any gauged fire extinguisher must be recharged after any use, or if the pressure gauge indicator falls outside of the green range (see NFPA 10). H3R Performance does not recharge fire extinguishers.

What are the inspection and maintenance requirements for my extinguisher? Install, inspect, maintain and test your fire extinguisher in accordance with the National Fire Protection Assoc. INSPECTION should be performed monthly or more frequently if circumstances dictate. The extinguisher should be checked to see that it is not damaged, the discharge outlet is not blocked, that it is fully charged, the seal is not broken and that the operating instructions are clearly visible.

ANNUAL MAINTENANCE is a more complete inspection of the extinguisher and should be done professionally. It will reveal the need for hydro testing which must be done on Dry Chemical and Halotron I extinguishers every TWELVE YEARS. Most local authorities require special tags be attached to the extinguisher to verify this service.

SIX YEAR MAINTENANCE - Every six years, extinguishers requiring a 12 year hydro test shall be emptied and subject to thorough examination of: mechanical parts, extinguishing agent and expelling means. When applicable maintenance procedures are done during periodic recharging or hydro testing, the six-year requirement will begin from that date.

RECHARGE should be done professionally immediately after any use by your local fire service company who has the trained personnel, extinguishing agents and equipment to do it properly. This extinguisher must be recharged with the extinguishing agent specified on the nameplate. Substitutions could cause damage or injury.